|     Written By: Dan Alcox     |     Date Posted: 02-26-2016     |

Key Takeaways

  • Know the affects of saltwater on electronics
  • See how saltwater damages electronics
  • Learn how to clean off saltwater residue

Pure distilled water does not conduct electricity and will not damage most electrical equipment that is clean and free of debris. Tap water is not pure water because it mixes with polarized minerals as it makes its way through your pipe. These polarized minerals are what makes water conduct electricity. This is how water, causes most electronics to short.

Salt water, on the other hand can be dangerous to electronics. This is due to the NaCI (Sodium chloride) creating a chemical bond with many surfaces. These bonds happen immediately upon wetting — resulting in a salt residue remaining long after the water is gone. Just one second of saltwater exposure can have the same effects as all day salt water exposure. Over a period of weeks, months or even years, the salt left behind continues to corrode any susceptible, affected surface. The corrosion process continues until the salt residue is exhausted or the corroded surface is consumed.

What Does this Have to Do with Sensors?

While our WR sensors are IP67 rated, saltwater can still cause problems when it comes to ranging. Once a sensor is splashed with saltwater, a residue forms on the transducer. It may not affect ranging immediately, but as the sensor gets repeatedly splashed, this residue continues to build. Eventually, the sensor may begin to report erratic distances or none at all. If the pin out of a WR sensor is not properly weather-proofed during installation, possible salt contamination may erode the connection causing sensor failure.

Figure 1. MB1000 & MB7066 before saltwater exposure

a sensor before saltwater a horn before salt water

Figure 2. MB1000 & MB7066 after saltwater exposure

a sensor after saltwater a horn after salt water

As you can see in Figure 2, the WR sensor has salt deposits in the horn and on transducer. If the residue is not neutralized it continues to build over the transducer which hinders or slows the sound wave and makes ranging difficult. The MB1000 sensor has salt deposits around the integrated circuits and all metal components. Until this residue is neutralized it continues to eat away at this board until the components are rusted and destroyed. This test was done with the indoor sensor to emphasize pin out damage, showing what salt can do to exposed circuitry and non-weatherproofed PCB material.

Figure 3. shows the PCB before (left) & after (right) saltwater exposure

a pcb board before saltwater a pcb board after saltwater


How to Neutralize Salt Residue

You can scrub for hours and the salt residue will remain, but you must neutralize the salt. There are products you can buy to accomplish neutralization, but you can also remove the residue by using isopropyl alcohol 90% or stronger.

Steps to Neutralize Salt Residue

  1. Remove from power source, then remove all wires, ribbon cables, anything that is attached.
  2. Take a soft bristled brush dip in isopropyl alcohol and gently scrub. Scrubbing too hard may cause more damage to the already fragile components.
  3. You may repeat this process until the residue is gone.
  4. Once board is clean, set to the side to dry.
  5. You need to clean every wire and cable that was removed. Pay particular attention to the connectors and ends of the ribbon cables to prevent corrosion of their contact surfaces.
  6. After the board and all parts are clean, use de-ionized water to rinse off the isopropyl alcohol residue.
  7. Do not reassemble until all components are dry and free of residue.

Contact our technical support team if you need any additional help or have any questions about sensor selection or technical support. We are here to help you succeed.



 
Author: Cody Carlson  Date: 08-02-2016
Raspberry Pi 2 board MaxSonar sensors offer a variety of outputs including TTL serial data. This tutorial guides you through the process of setting up your Raspberry Pi 3 with a MaxBotix sensor. Click here for full article.
Author: Scott Wielenberg  Date: 07-26-2016
Full Horn Housing MaxBotix offers an expanded range of packaging options for many of our sensors. Each option provides unique benefits to certain mounting integrations. This article provides a brief overview of each option.
Click here for full article.
Author: Scott Wielenberg  Date: 07-18-2016
Sensor is Tested When providing support, our technical support team may determine that further testing at our facility is the best way to help resolve the issue that you are facing. At this point, they will start the Return Merchandise Authorization (RMA) process. This article will explain what you can expect as your ultrasonic sensor travels through our RMA process.
Click here for full article.
Author: Scott Wielenberg  Date: 07-11-2016
Typical Wall Pipe Many customers have requested the option to mount an ultrasonic sensor in a pipe. During the testing and development cycle, we discovered a number of considerations and requirements that must be met for the application to be successful. When all of these are met, a user may be able to achieve the desired level of success for measuring the liquid level inside of a pipe.
Click here for full article.
Author: Jenney Grover  Date: 06-28-2016
one of the options for outputs On April 19th, we welcomed our supporters to join us for the Grand Opening of the Build Out. Bob and Nita Gross gave a tour of the build out and their vision for the space. We continue to be in awe of the support from our community, our employees, our distributors, and our customers. Thank you for the many years of support, and we look forward to serving you in the years to come.
Click here for full article.
 
 
 
 
 
Signup for notification of our exciting new products and periodic new letters. We are excited to provide the latest information from MaxBotix Inc.