Key Takeaways

  • Oscilloscopes display the properties of electrical signals as they change over time
  • Most oscilloscopes offer a number of tools or options to measure electrical signals
  • Proper triggering helps to fix the waveform in one spot on the display

An oscilloscope displays electrical signals as they change over time. Understanding the operation of an oscilloscope allows for in depth examination of a circuit and/or electrical components. Oscilloscopes measure noise levels, cycle frequency, and other electrical specifications of a circuit. This guide covers the basic use and features of an oscilloscope.

Quick Start Guide

PicoScope After powering the oscilloscope, connect or locate an attached oscilloscope probe [Figure 1]. The probes typically twist on and off of the oscilloscope and can be replaced or exchanged. Each probe should have a spring-loaded cap that allows the oscilloscope to be clipped onto wires or pins. This end cap can be removed to expose a pointed tip for testing finer leads and vias. The last element of the probe is typically a gator clip to connect to the ground terminal of the tested device.

Probe Once the scope probes are properly connected, the oscilloscope displays the observed waveform information. Oscilloscopes typically designate both vertical and horizontal controls. Depending on the vertical and horizontal scaling, you may need to locate this waveform. The Volts/Div dial controls the vertical scaling, and the Sec/Div dial controls the horizontal scaling. Each set of controls should also have a position knob to help locate and align waveforms.

With the waveform in the view window, setting an appropriate trigger point allows continuous and easy observation of the waveform. Without proper triggering, the waveform will move across the screen and may not provide a clear picture. Triggering helps to hold a waveform stable on the screen and displays the signals of interest. For basic triggering, select a rising or falling edge as the trigger method and adjust the trigger level to sit below the peak or above the bottom of the waveform for the two respective trigger methods.

Clearly displayed waveforms in the view window allows you to capture signal measurements. As well as having designated vertical and horizontal controls, many oscilloscopes have a series of menus for capturing information about the waveform. Measure and cursor menus help to take measurements of voltage and frequency. The acquire menu will let you store the displayed waveform for future comparison. These additional controls should enable you to capture the information you need.

Additional Controls

Vertical Controls

Position Position is used to shift the waveform higher or lower on the screen
Volts/Div Volts/Div adjusts the vertical scaling
Coupling Coupling allows you select if the probe is being connected to an AC or DC power source
BW Limit Restricts the frequencies that you are observing to cut down on noise (higher restrictions may remove valuable information along with noise)
Volts/Div Adjusts how much turning the Volts/Div knob does
Probe Adjusts this setting to match the attenuation setting on the probe
Invert Inverts the reported waveform

Horizontal Controls

Position Position is used to shift the waveform left or right on the screen
Sec/Div Sec/Div adjusts the horizontal scaling

Trigger Controls

Type Edge is basic and it looks for a rising or falling edge at a specific amplitude
Source Allows selecting what source is monitored for the trigger
Slope Allows you to determine if you are looking for a rising or falling slope to trigger the oscilloscope
Level Sets the height of the trigger voltage level
Set to 50% Places the trigger between the peaks of the signal

Additional Menus

Measure Provides an assortment of measurement options such as measuring average voltage or period length
Acquire Allows you to save the waveform in the oscilloscope’s memory
Cursor Allows you to place cursors on the oscilloscope screen to mark key features which can be used to measure time and voltage

Reading Controls

Single Seq. Allows the oscilloscope to take one reading, display the reading, and stop
Run/Stop Allows continuous display reading and updating

Author: Kathy Kostal  Date: 08-31-2016
Inc 5000 Maxbotix Logo Inc. Magazine Unveils 35th Annual List of America's Fastest Growing Private Companies–the Inc. 5000. MaxBotix Inc., Ranks No. 1752 on the 2016 Inc. 5000 with Three–Year Sales Growth of 213%.
Click here for full article.
Author: Cody Carlson  Date: 08-02-2016
Raspberry Pi 2 board MaxSonar sensors offer a variety of outputs including TTL serial data. This tutorial guides you through the process of setting up your Raspberry Pi 3 with a MaxBotix sensor. Click here for full article.
Author: Scott Wielenberg  Date: 07-26-2016
Full Horn Housing MaxBotix offers an expanded range of packaging options for many of our sensors. Each option provides unique benefits to certain mounting integrations. This article provides a brief overview of each option.
Click here for full article.
Author: Scott Wielenberg  Date: 07-18-2016
Sensor is Tested When providing support, our technical support team may determine that further testing at our facility is the best way to help resolve the issue that you are facing. At this point, they will start the Return Merchandise Authorization (RMA) process. This article will explain what you can expect as your ultrasonic sensor travels through our RMA process.
Click here for full article.
Author: Scott Wielenberg  Date: 07-11-2016
Typical Wall Pipe Many customers have requested the option to mount an ultrasonic sensor in a pipe. During the testing and development cycle, we discovered a number of considerations and requirements that must be met for the application to be successful. When all of these are met, a user may be able to achieve the desired level of success for measuring the liquid level inside of a pipe.
Click here for full article.
Author: Jenney Grover  Date: 06-28-2016
one of the options for outputs On April 19th, we welcomed our supporters to join us for the Grand Opening of the Build Out. Bob and Nita Gross gave a tour of the build out and their vision for the space. We continue to be in awe of the support from our community, our employees, our distributors, and our customers. Thank you for the many years of support, and we look forward to serving you in the years to come.
Click here for full article.
Signup for notification of our exciting new products and periodic new letters. We are excited to provide the latest information from MaxBotix Inc.